Church emergency exits in Brazil must follow the rules of the fire department in your state because churches are public assembly spaces: the regulations define the number and width of doors, aisles, and evacuation routes based on the sanctuary's occupant capacity. Pew placement must respect these routes, so the layout must be approved by the licensed professional responsible for the project.

This article offers general guidance from a church pew manufacturer that has been in business since 1965 and receives church floor plans from across Brazil. It does not replace a design prepared by a licensed professional or consultation of official regulations, which are updated over time.

A church is a public assembly space

Fire safety regulations classify buildings by occupancy type. Sanctuaries, chapels, and worship halls bring many people together in one space at the same time, so they fall into the public assembly category. For example, Ordinance 087/2015 of the Rio Grande do Norte Fire Department addresses buildings classified for religious use under Group F, Division F-2.

In practice, this means the sanctuary needs exits sized for its occupant capacity, signs, emergency lighting, and other measures required by your state's regulations. The responsible professional determines your sanctuary's exact classification based on local regulations.

Who sets the rules in your Brazilian state?

Each Brazilian state has its own fire department and regulations. In São Paulo, for example:

  • State Decree 63.911/2018 establishes the Fire Safety Regulations for buildings and hazardous areas;
  • the Technical Instructions issued by the São Paulo State Military Police Fire Department detail each safety measure, and Technical Instruction 11 covers emergency exits;
  • ABNT NBR 9077, Emergency Exits in Buildings, is the reference technical standard on this subject.

The Technical Instructions have gone through several editions over the years. Before designing a project, check the current version on the São Paulo Fire Department website or your state's fire department website. Outside São Paulo, the names vary (Technical Instruction, Technical Standard, Ordinance), but the approach is similar.

Occupancy limits, doors, and aisles

The calculation starts with occupant capacity: how many people the sanctuary can accommodate. Based on that, state regulations determine:

  1. how many exits the worship hall needs and the distance between them;
  2. the minimum width of doors, aisles, and stairs;
  3. the maximum distance a person may travel to reach an exit;
  4. how doors open and when panic hardware is required;
  5. signs and lighting along evacuation routes.

These figures are specified in the regulations and vary by state, building area, height, and occupancy. That is why this article does not provide exit counts or widths: they must come from a design signed by a licensed professional.

Balconies and mezzanines need special attention because evacuation routes from upper levels involve stairs, which must also be included in the calculations. Churches with balconies, such as CCB Fernandópolis/SP, where Zanovello installed Z-Elegance pews on the main floor and balcony, show why pews on both levels must respect the aisles specified in the design.

How pew placement affects evacuation routes

Pews occupy most of the worship hall and determine where people walk. If they are longer than specified in the design, they narrow an aisle; if placed incorrectly, they block access. Key precautions:

  • Keep aisles clear at the specified width, from the first pew to the last.
  • Give each row access to an aisle, without making anyone pass too many people to leave.
  • Keep the space in front of doors clear, with no pews, tables, or sound equipment in the way.
  • Keep pews firmly in place, so they do not slide into the aisle during worship.

This is where custom-made pews help. The Móveis Zanovello team receives the floor plan or worship hall measurements and calculates each pew's length and the row layout. When the plan already includes aisles defined by the responsible professional, those aisles are the starting point: the pews fit the hall, and the hall retains the planned evacuation routes. See how seating sections work at CCB Palestina/SP, with Z-Elegance pews separated by aisles, or at Assembleia de Deus de Cacoal/RO, with Z-Especial pews arranged in three seating sections.

Sections of Z-Elegance upholstered church pews separated by aisles at CCB Palestina/SP, viewed from the pulpit area

For details on spacing and rows, read church pew spacing, how many pews fit in a church, and church floor plans: how to arrange pews.

AVCB and CLCB: when churches in Brazil need them

In São Paulo, fire department compliance is documented through two types of certificates:

  • AVCB (Fire Department Inspection Certificate): issued after an inspection for buildings that require a technical design.
  • CLCB (Fire Department Licensing Certificate): a simplified process for lower-risk buildings that meet the regulatory criteria.

Which certificate the sanctuary needs depends on its area, height, occupant capacity, and occupancy type under current regulations. Other states may use different document names. Without a current license, the church may face issues with municipal authorities, insurance, and, most importantly, the safety of those attending services.

Where to find official regulations

  • Your state's fire department: regulations, current Technical Instructions or Standards, and license application guidance.
  • ABNT: NBR 9077 and the other standards cited in the design.
  • Municipal authorities: requirements for the operating permit and certificate of occupancy.
  • A licensed professional: an engineer with an ART registered with CREA or an architect with an RRT registered with CAU, who prepares the fire prevention and protection design and oversees the approval process.

Accessibility goes hand in hand with evacuation routes: Brazilian Law 13.146/2015 requires accessible evacuation routes and emergency exits in assembly spaces. See church accessibility.

Center aisle with beige Z-Elegance upholstered church pews on both sides at CCB Fernandópolis/SP

Next step

Once the floor plan is approved or the layout is validated by the responsible professional, send the files to Móveis Zanovello. The team calculates each pew's length while respecting the aisles specified in the design. Build your quote or contact us on WhatsApp: the proposal includes each pew's measurements, the timeline, and a 7-year written warranty. In Brazil, installation is handled by the factory's own team; churches abroad receive the pews shipped unassembled, without installation. The minimum order is 20 pews.

FAQ

Frequently asked questions

Talk to our team
Does a church need an AVCB?

In São Paulo, every public assembly building must have fire department approval through an AVCB or CLCB, depending on its area, height, occupant capacity, and occupancy type. Other Brazilian states use their own document names. The professional responsible for the design identifies which applies to the sanctuary.

How many emergency exits does a church need?

The number depends on the building's occupant capacity, area, and height and is determined by the state fire department's regulations. In São Paulo, the reference is the current version of Technical Instruction 11, Emergency Exits. A licensed engineer or architect must perform the calculations.

Can pews be placed against the wall?

It depends on the approved design for the sanctuary. Some layouts include side aisles along the walls, while others do not, depending on occupant capacity and evacuation routes. Móveis Zanovello calculates pew lengths using the floor plan with aisles defined by the responsible professional.

Who prepares the fire prevention design?

The design is prepared by a licensed professional: an engineer with an ART registered with CREA or an architect with an RRT registered with CAU. This professional classifies the building, calculates exit requirements, and oversees fire department approval. The pew manufacturer works from that design.

Custom-made pews for your church, with a 7-year warranty.
Chat on WhatsApp
Build your quote